MEASUREMENTS
Mode 1:
Time interval
between excitation pulse and first backwall echo, using contact
transducers.
Mode 2:
Time interval
between the first interface echo after the excitation pulse and the
first backwall echo, using delay line or immersion transducers.
Mode 3:
Time interval
between successive backwall echoes following the first interface echo
after the excitation pulse, using delay line and immersion transducers.
Measurement Types:
Thickness,
Velocity and Time of Flight
Pulser Configuration:
Pulse Echo,
Pitch Catch and Thru-Transmission
Thickness Measurement
Range:
Pulse Echo and Pitch
Catch
Steel: 0.050 - 25.000 inches
(1.27 - 635.00 mm)
Plastic: 0.030 - 3.00 inches
(0.75 - 75.00 mm)
Thru-Transmission
Steel: 0.075 - 50.000 inches
(1.91 - 1270.0 mm)
Plastic: 0.035 - 6.000 inches
(0.89 - 152.00 mm)
Thickness range
depends on material, transducer, surface condition and setup selected,
extended thickness ranges are possible using custom setups.
Material Velocity Range:
0.02000 - 0.55110 inch/΅S
(0.5080 - 13.9979 mm/΅S)
Thickness resolution,
keypad selectable:
LOW: 0.01" 0.1 mm
STANDARD: 0.001" 0.01 mm
Velocity resolution,
keypad selectable:
LOW: 0.001 inch/΅S 0.01 mm/΅S
STANDARD: 0.0001 inch/΅S
0.001 mm/΅S
Time of filght
resolution:
0.001 inch/΅S 0.01 mm/΅S
Measurement Rate:
4, 8, 12, 16 or 20
measurements per second
Transducer Frequency
Range: 0.5 - 5.0
MHz
Min/Max Mode:
Displays
current thickness, minimum thickness, or maximum thickness depending
on setting.
Display Hold/Blank:
Display blanks
after last reading or holds reading.
Zoom Mode:
Expands the
horizontal span of the waveform to the minimum range associated with
each transducer and automatically centers the measured echoes.
Freeze Mode:
Freeze and Un-Freeze
live Ascan with thickness.
Rectification:
RF, half wave
positive or negative, and full wave
Waveform Display Range
and Delay
Control:
The horizontal
span of the waveform is set at selected intervals with a fully
adjustable delay.
Alarm Mode:
Programmable
Hi-Low alarm set points with audible and visual indicators.
Differential Mode:
Displays
thickness difference between actual measurement and preset reference
value.
Application Auto-Recall:
Automatically
adjusts internal parameters and zero offset for a wide variety of
transducers.
Stored Standard Setups: 25
stored transducer setups allow fast, easy calibration for Panametrics-NDT
standard transducers.
Stored Custom Setups:
Up to 35
stored custom transducer setups for best performance in special
applications. |
POWER SUPPLY
Battery:
6 V
Rechargeable NiCad battery pack
Battery Life:
25 hrs nominal
(with backlight off)
Low Battery Indicator:
Active display
shows percentage of remaining battery life
Charger:
Two hour fast
fast charger with universal voltage
Auto Power On/Off
GENERAL
Keypad:
Sealed color
coded keypad with tactile and audible feedback
Thickness Display:
5-Digit LCD
with Backlight. 0.5" (12.7 mm) numerals. Viewable area 2.2" x 1.5"
(56.3 x 38.4 mm)
Backlight:
Electroluminescent backlit display. With power save feature
Multi-Language Display:
Keypad
selectable display languages. Included are English, French, German,
and Spanish
Operating Temperature:
-10°C to +50°C (+14°F to 122°F)
Size:
9.375 x 5.45 x
1.5" (238 x 138 x 38 mm)
Weight:
2.1 lbs (0.95
kg)
INTERNAL DATALOGGER
Datalogger and RS-232:
The 25HP PLUS
identifies, stores, recalls, clears, and transmits thickness readings,
waveform images, and gage setup information via the RS-232 Serial Port.
Baud Rate, Word Length, Stop Bits, and Parity are adjustable from the
keypad.
Maximum # of Stored
Values:
Standard:
18,000
thickness readings or 1,700 waveforms with thickness
Upgrade 1:
36,000
thickness readings or 3,400 waveforms with thickness.
Upgrade 2:
54,000
thickness readings or 5,100 waveforms with thickness.
Location Codes:
8-character
file name plus 16-character alphanumeric location code input. Multiple
Comments per location.
File Structures:
Data can be
stored in 7 standard or custom application-specific file structures.
Reports:
On-gage
reporting of: Summary with statistics, Min/Max with locations, and
File Comparison. On-screen Comparison of current and previous readings
OPTIONAL ACCESSORIES
-
HPV/C
Digital Caliper for Thickness Input
-
PLUS/RPC
Protective Rubber Boot with Stand and Straps
-
36DLP/SPC/KIT
Protective Pouch with Neck Strap
-
Win25DLPLUS
Interface
Program
-
25DLP/EW
Extended Limited Warranty
-
2214E
5-Step Test Block, 1018 steel, English Units: .100",
.200", .300", .400", .500"
-
2213E
5-Step Test Block, Aluminum, English Units: .100",
.200", .300", .400", .500"
-
26DLPLUS/HDC
Heavy Duty
Shipping Case
|